Before yesterdayUS-CERT Current Activity

CISA and FBI Release Secure by Design Alert to Urge Manufacturers to Eliminate Directory Traversal Vulnerabilities

By: CISA
2 May 2024 at 08:00

Today, CISA and the Federal Bureau of Investigation (FBI) released a joint Secure by Design Alert, Eliminating Directory Traversal Vulnerabilities in Software. This Alert was crafted in response to recent well-publicized threat actor campaigns that exploited directory traversal vulnerabilities in software (e.g., CVE-2024-1708, CVE-2024-20345) to compromise users of the software—impacting critical infrastructure sectors, including the Healthcare and Public Health Sector.

Additionally, this Alert highlights the prevalence, and continued threat actor exploitation of, directory traversal defects. Currently, CISA has listed 55 directory traversal vulnerabilities in our Known Exploited Vulnerabilities (KEV) catalog. Approaches to avoid directory traversal vulnerabilities are known, yet threat actors continue to exploit these vulnerabilities which have impacted the operation of critical services, including hospital and school operations.

CISA and the FBI urge software manufacturer executives to require their organizations to conduct formal testing to determine their products’ susceptibility to directory traversal vulnerabilities.

For more information on recommended principles and best practices to achieve this goal, visit CISA’s Secure by Design page. To catch up on the publications in this series, visit Secure by Design Alerts.

CISA Releases Three Industrial Control Systems Advisories

By: CISA
2 May 2024 at 08:00

CISA released three Industrial Control Systems (ICS) advisories on May 02, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Delta Electronics DIAEnergie

By: CISA
2 May 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.3
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Delta Electronics
  • Equipment: DIAEnergie
  • Vulnerabilities: SQL Injection, Path Traversal

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an authenticated attacker with limited privileges to escalate privileges, retrieve confidential information, upload arbitrary files, backdoor the application, and compromise the system on which DIAEnergie is deployed.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Delta Electronics DIAEnergie, an industrial energy management system, are affected:

  • DIAEnergie: Versions v1.10.00.005

3.2 Vulnerability Overview

3.2.1 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

CVE-2024-34031 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-34031. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89

Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.

CVE-2024-34032 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-34032. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.3 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') CWE-22

Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.

CVE-2024-34033 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-34033. A base score of 9.3 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Michael Heinzl reported these vulnerabilities to CISA.

4. MITIGATIONS

Delta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics' regional sales or agents.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 02, 2024: Initial Publication

CyberPower PowerPanel

By: CISA
2 May 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/Low attack complexity
  • Vendor: CyberPower
  • Equipment: PowerPanel
  • Vulnerabilities: Use of Hard-coded Password, Relative Path Traversal, Use of Hard-coded Credentials, Active Debug Code, Storing Passwords in a Recoverable Format, Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection'), Use of Hard-coded Cryptographic Key, Improper Authorization

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could result in an attacker bypassing authentication and gaining administrator privileges, forging JWT tokens to bypass authentication, writing arbitrary files to the server and achieving code execution, gaining access to services with the privileges of a PowerPanel application, gaining access to the testing or production server, learning passwords and authenticating with user or administrator privileges, injecting SQL syntax, writing arbitrary files to the system, executing remote code, impersonating any client in the system and sending malicious data, or obtaining data from throughout the system after gaining access to any device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of PowerPanel, a business management software, are affected:

  • PowerPanel: 4.9.0 and prior

3.2 Vulnerability Overview

3.2.1 USE OF HARD-CODED PASSWORD CWE-259

The application code contains a hard-coded set of authentication credentials. This could result in an attacker bypassing authentication and gaining administrator privileges.

CVE-2024-34025 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.2 USE OF HARD-CODED PASSWORD CWE-259

The application code contains a hard-coded JWT signing key. This could result in an attacker forging JWT tokens to bypass authentication.

CVE-2024-34025 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.3 RELATIVE PATH TRAVERSAL CWE-23

A specially crafted Zip file containing path traversal characters can be imported to the server, which allows file writing to the server outside the intended scope, and could allow an attacker to achieve remote code execution.

CVE-2024-33615 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.4 USE OF HARD-CODED CREDENTIALS CWE-798

Hard-coded credentials are used by the platform to authenticate to the database, other services, and the cloud. This could result in an attacker gaining access to services with the privileges of a Powerpanel application.

CVE-2024-32053 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.5 ACTIVE DEBUG CODE CWE-489

Hard-coded credentials for the test server can be found in the production code. This might result in an attacker gaining access to the testing or production server.

CVE-2024-32047 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.6 STORING PASSWORDS IN A RECOVERABLE FORMAT CWE-257

The key used to encrypt passwords stored in the database can be found in the application code, allowing the passwords to be recovered.

CVE-2024-32042 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

3.2.7 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN SQL COMMAND ('SQL INJECTION') CWE-89

An attacker with certain MQTT permissions can create malicious messages to all Power Panel devices. This could result in an attacker injecting SQL syntax, writing arbitrary files to the system, and executing remote code.

CVE-2024-31856 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.8 USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321

The devices Power Panel manages use identical certificates based on a hard-coded cryptographic key. This can allow an attacker to impersonate any client in the system and send malicious data.

CVE-2024-31410 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N).

3.2.9 IMPROPER AUTHORIZATION CWE-285

Certain MQTT wildcards are not blocked on the system, which might result in an attacker obtaining data from throughout the system after gaining access to any device.

CVE-2024-31409 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Amir Preminger and Noam Moshe of Claroty Team82 Research reported these vulnerabilities to CISA.

4. MITIGATIONS

CyberPower has released a new version of PowerPanel that fixes these vulnerabilities:

PowerPanel Business: Update to v4.10.1 or later version

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • May 02, 2024: Initial Publication

CISA Adds One Known Exploited Vulnerability to Catalog

By: CISA
1 May 2024 at 08:00

CISA has added one new vulnerability to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2023-7028 GitLab Community and Enterprise Editions Improper Access Control Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

CISA and Partners Release Fact Sheet on Defending OT Operations Against Ongoing Pro-Russia Hacktivist Activity

By: CISA
1 May 2024 at 08:00

Today, CISA, in collaboration with U.S. and international partners, published a joint fact sheet, Defending OT Operations Against Ongoing Pro-Russia Hacktivist Activity. This fact sheet provides information and mitigations associated with cyber operations conducted by pro-Russia hacktivists who seek to compromise industrial control systems (ICS) and small-scale operational technology (OT) systems in North American and European critical infrastructure sectors, including Water and Wastewater Systems, Dams, Energy, and Food and Agriculture Sectors.

The pro-Russia hacktivist activity appears mostly limited to unsophisticated techniques that manipulate ICS equipment to create nuisance effects. However, investigations have identified that these actors are capable of techniques that pose physical threats against insecure and misconfigured OT environments.

CISA and partners encourage OT operators in critical infrastructure sectors to apply the recommendations listed in the fact sheet to defend against this activity. To learn more about secure by design principles and practices, visit CISA's Secure by Design webpage. For more information and guidance on protection against the most common and impactful threats, tactics, techniques, and procedures, visit CISA’s Cross-Sector Cybersecurity Performance Goals.

CERT/CC Reports R Programming Language Vulnerability

By: CISA
1 May 2024 at 08:00

CERT Coordination Center (CERT/CC) has released information on a vulnerability in R programming language implementations (CVE-2024-27322). A cyber threat actor could exploit this vulnerability to take control of an affected system.

Users and administrators are encouraged to review the following advisories and apply the necessary updates:

CISA Adds One Known Exploited Vulnerability to Catalog

By: CISA
30 April 2024 at 08:00

CISA has added one new vulnerability to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2024-29988 Microsoft SmartScreen Prompt Security Feature Bypass Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Delta Electronics CNCSoft-G2 DOPSoft

By: CISA
30 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.5
  • ATTENTION: Low attack complexity
  • Vendor: Delta Electronics
  • Equipment: CNCSoft-G2 DOPSoft
  • Vulnerability: Stack-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Delta Electronics CNCSoft-G2, a Human-Machine Interface (HMI) software, are affected:

  • CNCSoft-G2: Versions 2.0.0.5 (with DOPSoft v5.0.0.93) and prior

3.2 Vulnerability Overview

3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121

Delta Electronics CNCSoft-G2 lacks proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.

CVE-2024-4192 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H ).

A CVSS v4 score has also been calculated for CVE-2024-4192. A base score of 8.5 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy, Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Taiwan

3.4 RESEARCHER

Natnael Samson working with Trend Micro Zero Day Initiative reported this vulnerability to CISA.

4. MITIGATIONS

Delta Electronics recommends users update to CNCSoft-G2 v2.1.0.4 or later.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • April 30, 2024: Initial Publication

CISA Releases Three Industrial Control Systems Advisories

By: CISA
30 April 2024 at 08:00

CISA released three Industrial Control Systems (ICS) advisories on April 30, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Siemens RUGGEDCOM APE1808 Devices Configured with Palo Alto Networks Virtual NGFW

By: CISA
25 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 
View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 10.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808
  • Vulnerability: Command Injection

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code with root privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens RUGGEDCOM APE1808, an application hosting platform, are affected:

  • RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW configured with GlobalProtect gateway or GlobalProtect portal (or both).

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77

A command injection as a result of arbitrary file creation vulnerability in the GlobalProtect feature of Palo Alto Networks PAN-OS software for specific PAN-OS versions and distinct feature configurations may enable an unauthenticated attacker to execute arbitrary code with root privileges on the firewall.

CVE-2024-3400 has been assigned to this vulnerability. A CVSS v3.1 base score of 10.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-3400. A base score of 10.0 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

RUGGEDCOM APE1808:

  • Contact customer support to receive patch and update information.
  • Disable GlobalProtect gateway and GlobalProtect portal; note that these features are disabled by default in RUGGEDCOM APE1808 deployments.
  • Customers with a Threat Prevention subscription can block attacks for this vulnerability using Threat IDs 95187, 95189, and 95191 (available in Applications and Threats content version 8836-8695 and later). For further instruction see Palo Alto Network's upstream notification (https://security.paloaltonetworks.com/CVE-2024-3400).

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-750274 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 25, 2024: Initial Publication

Multiple Vulnerabilities in Hitachi Energy RTU500 Series

By: CISA
25 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.0
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Hitachi Energy
  • Equipment: RTU500 Series
  • Vulnerabilities: Unrestricted Upload of File with Dangerous Type

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow the attacker to upload or transfer files of dangerous types that can be automatically processed within the product's environment.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Hitachi's RTU500 series CMU Firmware are affected:

  • RTU500 series CMU Firmware: Version 12.0.1 - 12.0.14
  • RTU500 series CMU Firmware: Version 12.2.1 - 12.2.11
  • RTU500 series CMU Firmware: Version 12.4.1 - 12.4.11
  • RTU500 series CMU Firmware: Version 12.6.1 - 12.6.9
  • RTU500 series CMU Firmware: Version 12.7.1 - 12.7.6
  • RTU500 series CMU Firmware: Version 13.2.1 - 13.2.6
  • RTU500 series CMU Firmware: Version 13.4.1 - 13.4.4
  • RTU500 series CMU Firmware: Version 13.5.1 - 13.5.3

3.2 Vulnerability Overview

3.2.1 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434

A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could print random memory content in the RTU500 system log, if an authorized user uploads a specially crafted stb-language file.

CVE-2024-1531 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:H).

A CVSS v4 score has also been calculated for CVE-2024-1531. A base score of 7.0 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N).

3.2.2 UNRESTRICTED UPLOAD OF FILE WITH DANGEROUS TYPE CWE-434

A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could enforce diagnostic texts being displayed as empty strings, if an authorized user uploads a specially crafted stb-language file.

CVE-2024-1532 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:C/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-1532. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Hitachi Energy reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi Energy has released the following mitigations for CVE-2024-1531 and CVE-2024-1532:

  • RTU500 series CMU Firmware Version 12.7.1 - 12.7.6: Update to CMU Firmware Version 12.7.7
  • RTU500 series CMU Firmware Version 13.2.1 - 13.2.6: Update to CMU Firmware Version 13.2.7

Until the updates are made available, Hitachi Energy recommends the following general mitigation factors/workarounds for the products with RTU500 series CMU firmware Versions 12.0.1 - 12.0.14, 12.2.1 - 12.2.11, 12.4.1 - 12.4.11, 12.6.1 - 12.6.9, 13.4.1 - 13.4.4, and 13.5.1 - 13.5.3 to address the vulnerabilities CVE-2024-1531 and CVE-2024-1532:

  • Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including.
  • Physically protect process control systems from direct access by unauthorized personnel.
  • Do not allow process control systems direct connections to the Internet.
  • Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.
  • Process control systems should not be used for Internet surfing, instant messaging, or receiving emails.
  • Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

For more information, see Hitachi Energy's Security Advisories:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. PUBLICATION HISTORY

  • April 25, 2024: Initial Publication

Honeywell Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, Safety Manager SC

By: CISA
25 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Honeywell
  • Equipment: Experion PKS, Experion LX, PlantCruise by Experion, Safety Manager, Safety Manager SC
  • Vulnerabilities: Exposed Dangerous Method or Function, Absolute Path Traversal, Stack-based Buffer Overflow, Debug Messages Revealing Unnecessary Information, Out-of-bounds Write, Heap-based Buffer Overflow, Binding to an Unrestricted IP Address, Improper Input Validation, Buffer Access with Incorrect Length Value, Improper Restriction of Operations within the Bounds of a Memory Buffer, Improper Handling of Length Parameter Inconsistency

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could disclose sensitive information, allow privilege escalation, or allow remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Honeywell reports these vulnerabilities affect the following versions of Experion PKS, LX, PlantCruise, Safety Manager, and Safety Manager SC:

  • Experion PKS: All releases prior to R510.2 HF14
  • Experion PKS: All releases prior to R511.5 TCU4 HF4
  • Experion PKS: All releases prior to R520.1 TCU5
  • Experion PKS: All releases prior to R520.2 TCU4 HF2
  • Experion LX: All releases prior to R511.5 TCU4 HF4
  • Experion LX: All releases prior to R520.1 TCU5
  • Experion LX: All releases prior to R520.2 TCU4 HF2
  • PlantCruise by Experion: All releases prior to R511.5 TCU4 HF4
  • PlantCruise by Experion: All releases prior to R520.1 TCU5
  • PlantCruise by Experion: All releases prior to R520.2 TCU4 HF2
  • Safety Manager: R15x, R16x up to and including R162.10
  • Safety Manager SC: R210.X, R211.1, R211.2, R212.1

3.2 Vulnerability Overview

3.2.1 Exposed Dangerous Method or Function CWE-749

Successful exploitation of this vulnerability could allow an attacker to modify files on Experion controllers or SMSC S300. This exploit could be used to write a file that may result in unexpected behavior based on configuration changes or updating of files that could result in subsequent execution of a malicious application if triggered.

CVE-2023-5389 has been assigned to this vulnerability. A CVSS v3 base score of 9.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5389. A base score of 8.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 Absolute Path Traversal CWE-36

Successful exploitation of this vulnerability could allow an attacker to read from the Experion controllers or SMSC S300. This exploit could be used to read files from the controller that may expose limited information from the device.

CVE-2023-5390 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-5390. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.3 Stack-based Buffer Overflow CWE-121

Successful exploitation of this vulnerability against the Experion controller, ControlEdge PLC, Safety Manager or SMSC S300 could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5407 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5407. A base score of 8.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 Debug Messages Revealing Unnecessary Information CWE-1295

Successful exploitation of this vulnerability against the Experion controller, ControlEdge PLC, Safety Manager or SMSC S300 could allow an attacker to extract more information from memory over the network than is required.

CVE-2023-5392 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-5392. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.5 Out-of-bounds Write CWE-787

Successful exploitation of this vulnerability against the Experion Servers or Stations by manipulation messages from a controller could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5406 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5406. A base score of 8.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.6 Out-of-bounds Write CWE-787

Successful exploitation of this vulnerability against the Experion Servers or Stations could result in an information leak when an error is generated.

CVE-2023-5405 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-5405. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.7 Heap-based Buffer Overflow CWE-122

Successful exploitation of these vulnerabilities against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5400 and CVE-2023-5404 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5400 and CVE-2023-5404. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.8 Stack-based Buffer Overflow CWE-121

Successful exploitation of these vulnerabilities against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5395, CVE-2023-5401 and CVE-2023-5403 have been assigned to these vulnerabilities. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5395, CVE-2023-5401 and CVE-2023-5403. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.9 Binding to an Unrestricted IP Address CWE-1327

Successful exploitation of this vulnerability against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition over the network using specially crafted messages.

CVE-2023-5398 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5398. A base score of 8.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.2.10 Improper Input Validation CWE-20

Successful exploitation of this vulnerability against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5397 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5397. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.11 Buffer Access with Incorrect Length Value CWE-805

Successful exploitation of this vulnerability against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5396 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5396. A base score of 8.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.12 Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-119

Successful exploitation of this vulnerability against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5394 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5394. A base score of 8.3 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.13 Improper Handling of Length Parameter Inconsistency CWE-130

Successful exploitation of this vulnerability against the Experion Servers or Stations could allow an attacker to cause a denial-of-service condition or perform a remote code execution over the network using specially crafted messages.

CVE-2023-5393 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2023-5393. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Chemical, Critical Manufacturing, Energy, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Claroty and Armis reported these vulnerabilities to Honeywell.

4. MITIGATIONS

Honeywell fixed the reported issues and advises users to upgrade to version referenced in the Security Notice or CVE record.
CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:

  • Ensure the least-privilege user principle is followed.
  • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolate them from business networks.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 25, 2024: Initial Publication

Hitachi Energy MACH SCM

By: CISA
25 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.9
  • ATTENTION: Exploitable remotely
  • Vendor: Hitachi Energy
  • Equipment: MACH SCM
  • Vulnerabilities: Improper Control of Generation of Code, Improper Neutralization of Directives in Dynamically Evaluated Code

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could result in an execution of arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of MACH SCM, are affected:

  • MACH SCM: Versions 4.0 to 4.5.x
  • MACH SCM: Versions 4.6 to 4.38

3.2 Vulnerability Overview

3.2.1 IMPROPER CONTROL OF GENERATION OF CODE CWE-94

SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.

CVE-2024-0400 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has also been calculated for CVE-2024-0400. A base score of 8.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:L).

3.2.2 IMPROPER NEUTRILIZATION OF DIRECTIVES IN DYNAMICALLY EVALUATED CODE CWE-95

Authenticated List control client can execute the LINQ query in SCM Server to present event as list for operator. An authenticated malicious client can send special LINQ query to execute arbitrary code remotely (RCE) on the SCM Server that an attacker otherwise does not have authorization to do.

CVE-2024-2097 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H ).

A CVSS v4 score has also been calculated for CVE-2024-2097. A base score of 8.8 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:H/SA:L).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Switzerland

3.4 RESEARCHER

Hitachi Energy reported these vulnerabilities to CISA.

4. MITIGATIONS

Hitachi Energy has released the following mitigation for CVE-2024-2097:

  • MACH SCM: Versions 4.6 to 4.38: Upgrade to MACH SCM Version 4.38.1

Until the updates are made available, Hitachi Energy recommends the following general mitigation factors/workarounds for the products with MACH SCM Versions 4.0 to 4.5.x to address the vulnerability CVE-2024-0400:

Recommended security practices and firewall configurations can help protect a process control network from attacks originating from outside the network including:

  • Physically protect process control systems from direct access by unauthorized personnel.
  • Do not allow process control systems direct connections to the Internet.
  • Separate process control systems from other networks by means of a firewall system that has a minimal number of ports exposed.
  • Process control systems should not be used for Internet surfing, instant messaging, or receiving emails.
  • Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

For more information, see Hitachi Energy's Security Advisories:

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities have a high attack complexity.

5. PUBLICATION HISTORY

  • April 25, 2024: Initial Publication

CISA Releases Eight Industrial Control Systems Advisories

By: CISA
25 April 2024 at 08:00

CISA released eight Industrial Control Systems (ICS) advisories on April 25, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Cisco Releases Security Updates Addressing ArcaneDoor, Vulnerabilities in Cisco Firewall Platforms

By: CISA
24 April 2024 at 08:00

Today, Cisco released security updates to address ArcaneDoor—exploitation of Cisco Adaptive Security Appliances (ASA) devices and Cisco Firepower Threat Defense (FTD) software. A cyber threat actor could exploit vulnerabilities (CVE-2024-20353, CVE-2024-20359, CVE-2024-20358) to take control of an affected system. 

Cisco has reported active exploitation of CVE 2024-20353 and CVE-2024-20359 and CISA has added these vulnerabilities to its Known Exploited Vulnerabilities Catalog

CISA strongly encourages users and administrators to apply the necessary updates, hunt for any malicious activity, report positive findings to CISA, and review the following articles for more information:

CISA Adds Three Known Exploited Vulnerabilities to Catalog

By: CISA
24 April 2024 at 08:00

CISA has added three new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. 

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

CISA Adds One Known Exploited Vulnerability to Catalog

By: CISA
23 April 2024 at 08:00

CISA has added one new vulnerability to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2022-38028 Microsoft Windows Print Spooler Privilege Escalation Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

CISA Releases Two Industrial Control Systems Advisories

By: CISA
23 April 2024 at 08:00

CISA released two Industrial Control Systems (ICS) advisories on April 23, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Cisco Releases Security Advisories for Cisco Integrated Management Controller

By: CISA
19 April 2024 at 08:00

Cisco has released security advisories for vulnerabilities in the Cisco integrated management controller. A remote cyber threat actor could exploit one of these vulnerabilities to take control of an affected system. 

Users and administrators are encouraged to review the following advisories and apply the necessary updates: 

#StopRansomware: Akira Ransomware

By: CISA
18 April 2024 at 08:00

SUMMARY

Note: This joint Cybersecurity Advisory (CSA) is part of an ongoing #StopRansomware effort to publish advisories for network defenders that detail various ransomware variants and ransomware threat actors. These #StopRansomware advisories include recently and historically observed tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) to help organizations protect against ransomware. Visit stopransomware.gov to see all #StopRansomware advisories and to learn more about other ransomware threats and no-cost resources.

The United States’ Federal Bureau of Investigation (FBI), Cybersecurity and Infrastructure Security Agency (CISA), Europol’s European Cybercrime Centre (EC3), and the Netherlands’ National Cyber Security Centre (NCSC-NL) are releasing this joint CSA to disseminate known Akira ransomware IOCs and TTPs identified through FBI investigations and trusted third party reporting as recently as February 2024.

Since March 2023, Akira ransomware has impacted a wide range of businesses and critical infrastructure entities in North America, Europe, and Australia. In April 2023, following an initial focus on Windows systems, Akira threat actors deployed a Linux variant targeting VMware ESXi virtual machines. As of January 1, 2024, the ransomware group has impacted over 250 organizations and claimed approximately $42 million (USD) in ransomware proceeds.

Early versions of the Akira ransomware variant were written in C++ and encrypted files with a .akira extension; however, beginning in August 2023, some Akira attacks began deploying Megazord, using Rust-based code which encrypts files with a .powerranges extension.  Akira threat actors have continued to use both Megazord and Akira, including Akira_v2 (identified by trusted third party investigations) interchangeably.

The FBI, CISA, EC3, and NCSC-NL encourage organizations to implement the recommendations in the Mitigations section of this CSA to reduce the likelihood and impact of ransomware incidents.

Download the PDF version of this report:

For a downloadable copy of IOCs, see:

AA24-109A STIX XML (XML, 114.01 KB )
AA24-109A STIX JSON (JSON, 67.80 KB )

TECHNICAL DETAILS

Note: This advisory uses the MITRE ATT&CK® for Enterprise framework, version 14. See MITRE ATT&CK for Enterprise for all referenced tactics and techniques.

Initial Access

The FBI and cybersecurity researchers have observed Akira threat actors obtaining initial access to organizations through a virtual private network (VPN) service without multifactor authentication (MFA) configured[1], mostly using known Cisco vulnerabilities [T1190CVE-2020-3259 and CVE-2023-20269.[2],[3],[4] Additional methods of initial access include the use of external-facing services such as Remote Desktop Protocol (RDP) [T1133], spear phishing [T1566.001][T1566.002], and the abuse of valid credentials[T1078].[4]

Persistence and Discovery

Once initial access is obtained, Akira threat actors attempt to abuse the functions of domain controllers by creating new domain accounts [T1136.002] to establish persistence. In some instances, the FBI identified Akira threat actors creating an administrative account named itadm.

According to FBI and open source reporting, Akira threat actors leverage post-exploitation attack techniques, such as Kerberoasting[5], to extract credentials stored in the process memory of the Local Security Authority Subsystem Service (LSASS) [T1003.001].[6] Akira threat actors also use credential scraping tools [T1003] like Mimikatz and LaZagne to aid in privilege escalation. Tools like SoftPerfect and Advanced IP Scanner are often used for network device discovery (reconnaissance) purposes [T1016] and net Windows commands are used to identify domain controllers [T1018] and gather information on domain trust relationships [T1482].

See Table 1 for a descriptive listing of these tools.

Defense Evasion

Based on trusted third party investigations, Akira threat actors have been observed deploying two distinct ransomware variants against different system architectures within the same compromise event. This marks a shift from recently reported Akira ransomware activity. Akira threat actors were first observed deploying the Windows-specific “Megazord” ransomware, with further analysis revealing that a second payload was concurrently deployed in this attack (which was later identified as a novel variant of the Akira ESXi encryptor, “Akira_v2”).

As Akira threat actors prepare for lateral movement, they commonly disable security software to avoid detection. Cybersecurity researchers have observed Akira threat actors using PowerTool to exploit the Zemana AntiMalware driver[4] and terminate antivirus-related processes [T1562.001].

Exfiltration and Impact

Akira threat actors leverage tools such as FileZilla, WinRAR [T1560.001], WinSCP, and RClone to exfiltrate data [T1048]. To establish command and control channels, threat actors leverage readily available tools like AnyDesk, MobaXterm, RustDesk, Ngrok, and Cloudflare Tunnel, enabling exfiltration through various protocols such as File Transfer Protocol (FTP), Secure File Transfer Protocol (SFTP), and cloud storage services like Mega [T1537] to connect to exfiltration servers.

Akira threat actors use a double-extortion model [T1657] and encrypt systems [T1486] after exfiltrating data. The Akira ransom note provides each company with a unique code and instructions to contact the threat actors via a .onion URL. Akira threat actors do not leave an initial ransom demand or payment instructions on compromised networks, and do not relay this information until contacted by the victim. Ransom payments are paid in Bitcoin to cryptocurrency wallet addresses provided by the threat actors. To further apply pressure, Akira threat actors threaten to publish exfiltrated data on the Tor network, and in some instances have called victimized companies, according to FBI reporting.

Encryption

Akira threat actors utilize a sophisticated hybrid encryption scheme to lock data. This involves combining a ChaCha20 stream cipher with an RSA public-key cryptosystem for speed and secure key exchange [T1486]. This multilayered approach tailors encryption methods based on file type and size and is capable of full or partial encryption. Encrypted files are appended with either a .akira or .powerranges extension. To further inhibit system recovery, Akira’s encryptor (w.exe) utilizes PowerShell commands to delete volume shadow copies (VSS) on Windows systems [T1490]. Additionally, a ransom note named fn.txt appears in both the root directory (C:) and each users’ home directory (C:\Users).

Trusted third party analysis identified that the Akira_v2 encryptor is an upgrade from its previous version, which includes additional functionalities due to the language it’s written in (Rust). Previous versions of the encryptor provided options to insert arguments at runtime, including:

  • -p --encryption_path (targeted file/folder paths)
  • -s --share_file (targeted network drive path)
  • -n --encryption_percent (percentage of encryption)
  • --fork (create a child process for encryption

The ability to insert additional threads allows Akira threat actors to have more granular control over the number of CPU cores in use, increasing the speed and efficiency of the encryption process. The new version also adds a layer of protection, utilizing the Build ID as a run condition to hinder dynamic analysis. The encryptor is unable to execute successfully without the unique Build ID. The ability to deploy against only virtual machines using “vmonly” and the ability to stop running virtual machines with “stopvm” functionalities have also been observed implemented for Akira_v2. After encryption, the Linux ESXi variant may include the file extension “akiranew” or add a ransom note named “akiranew.txt” in directories where files were encrypted with the new nomenclature.

Leveraged Tools

Table 1 lists publicly available tools and applications Akira threat actors have used, including legitimate tools repurposed for their operations. Use of these tools and applications should not be attributed as malicious without analytical evidence to support threat actor use and/or control.

Table 1: Tools Leveraged by Akira Ransomware Actors
Name Description
AdFind AdFind.exe is used to query and retrieve information from Active Directory.
Advanced IP Scanner A network scanner is used to locate all the computers on a network and conduct a scan of their ports. The program shows all network devices, gives access to shared folders, and provides remote control of computers (via RDP and Radmin).
AnyDesk A common software that can be maliciously used by threat actors to obtain remote access and maintain persistence [T1219]. AnyDesk also supports remote file transfer.
LaZagne Allows users to recover stored passwords on Windows, Linux, and OSX systems.
PCHunter64 A tool used to acquire detailed process and system information [T1082].[7]
PowerShell A cross-platform task automation solution made up of a command line shell, a scripting language, and a configuration management framework, which runs on Windows, Linux, and macOS.
Mimikatz Allows users to view and save authentication credentials such as Kerberos tickets.
Ngrok A reverse proxy tool [T1090] used to create a secure tunnel to servers behind firewalls or local machines without a public IP address.
RClone A command line program used to sync files with cloud storage services [T1567.002] such as Mega.
SoftPerfect A network scanner (netscan.exe) used to ping computers, scan ports, discover shared folders, and retrieve information about network devices via Windows Management Instrumentation (WMI), Simple Network Management Protocol (SNMP), HTTP, Secure Shell (SSH) and PowerShell. It also scans for remote services, registry, files, and performance counters.
WinRAR Used to split compromised data into segments and to compress [T1560.001] files into .RAR format for exfiltration.
WinSCP Windows Secure Copy is a free and open source SSH File Transfer Protocol, File Transfer Protocol, WebDAV, Amazon S3, and secure copy protocol client. Akira threat actors have used it to transfer data [T1048] from a compromised network to actor-controlled accounts.

Indicators of Compromise

Disclaimer: Investigation or vetting of these indicators is recommended prior to taking action, such as blocking.

Table 2a: Malicious Files Affiliated with Akira Ransomware
File Name Hash (SHA-256) Description
w.exe d2fd0654710c27dcf37b6c1437880020824e161dd0bf28e3a133ed777242a0ca Akira ransomware
Win.exe dcfa2800754e5722acf94987bb03e814edcb9acebda37df6da1987bf48e5b05e Akira ransomware encryptor
AnyDesk.exe bc747e3bf7b6e02c09f3d18bdd0e64eef62b940b2f16c9c72e647eec85cf0138 Remote desktop application
Gcapi.dll 73170761d6776c0debacfbbc61b6988cb8270a20174bf5c049768a264bb8ffaf DLL file that assists with the execution of AnyDesk.exe
Sysmon.exe 1b60097bf1ccb15a952e5bcc3522cf5c162da68c381a76abc2d5985659e4d386 Ngrok tool for persistence
Config.yml Varies by use Ngrok configuration file
Rclone.exe aaa647327ba5b855bedea8e889b3fafdc05a6ca75d1cfd98869432006d6fecc9 Exfiltration tool
Winscp.rnd 7d6959bb7a9482e1caa83b16ee01103d982d47c70c72fdd03708e2b7f4c552c4 Network file transfer program
WinSCP-6.1.2-Setup.exe 36cc31f0ab65b745f25c7e785df9e72d1c8919d35a1d7bd4ce8050c8c068b13c Network file transfer program
Akira_v2

3298d203c2acb68c474e5fdad8379181890b4403d6491c523c13730129be3f75

0ee1d284ed663073872012c7bde7fac5ca1121403f1a5d2d5411317df282796c

Akira_v2 ransomware
Megazord

ffd9f58e5fe8502249c67cad0123ceeeaa6e9f69b4ec9f9e21511809849eb8fc

dfe6fddc67bdc93b9947430b966da2877fda094edf3e21e6f0ba98a84bc53198

131da83b521f610819141d5c740313ce46578374abb22ef504a7593955a65f07

9f393516edf6b8e011df6ee991758480c5b99a0efbfd68347786061f0e04426c

9585af44c3ff8fd921c713680b0c2b3bbc9d56add848ed62164f7c9b9f23d065

2f629395fdfa11e713ea8bf11d40f6f240acf2f5fcf9a2ac50b6f7fbc7521c83

7f731cc11f8e4d249142e99a44b9da7a48505ce32c4ee4881041beeddb3760be

95477703e789e6182096a09bc98853e0a70b680a4f19fa2bf86cbb9280e8ec5a

0c0e0f9b09b80d87ebc88e2870907b6cacb4cd7703584baf8f2be1fd9438696d

C9c94ac5e1991a7db42c7973e328fceeb6f163d9f644031bdfd4123c7b3898b0

Akira “Megazord” ransomware
VeeamHax.exe aaa6041912a6ba3cf167ecdb90a434a62feaf08639c59705847706b9f492015d Plaintext credential leaking tool
Veeam-Get-Creds.ps1 18051333e658c4816ff3576a2e9d97fe2a1196ac0ea5ed9ba386c46defafdb88 PowerShell script for obtaining and decrypting accounts from Veeam servers
PowershellKerberos TicketDumper 5e1e3bf6999126ae4aa52146280fdb913912632e8bac4f54e98c58821a307d32 Kerberos ticket dumping tool from LSA cache
sshd.exe 8317ff6416af8ab6eb35df3529689671a700fdb61a5e6436f4d6ea8ee002d694 OpenSSH Backdoor
ipscan-3.9.1-setup.exe 892405573aa34dfc49b37e4c35b655543e88ec1c5e8ffb27ab8d1bbf90fc6ae0 Network scanner that scans IP addresses and ports
Table 2b: Malicious Files Affiliated with Akira Ransomware
File Name Hash (MD5) Description
winrar-x64-623.exe 7a647af3c112ad805296a22b2a276e7c Network file transfer program

Disclaimer: While the date/time can be changed by Akira threat actors, trusted third-party analysis confirmed these samples were created on December 28, 2023.

Table 3: Windows Akira Ransomware Samples
Hash (SHA-256)
0b5b31af5956158bfbd14f6cbf4f1bca23c5d16a40dbf3758f3289146c565f43
0d700ca5f6cc093de4abba9410480ee7a8870d5e8fe86c9ce103eec3872f225f
a2df5477cf924bd41241a3326060cc2f913aff2379858b148ddec455e4da67bc
03aa12ac2884251aa24bf0ccd854047de403591a8537e6aba19e822807e06a45
2e88e55cc8ee364bf90e7a51671366efb3dac3e9468005b044164ba0f1624422
40221e1c2e0c09bc6104548ee847b6ec790413d6ece06ad675fff87e5b8dc1d5
5ea65e2bb9d245913ad69ce90e3bd9647eb16d992301145372565486c77568a2
643061ac0b51f8c77f2ed202dc91afb9879f796ddd974489209d45f84f644562
6f9d50bab16b2532f4683eeb76bd25449d83bdd6c85bf0b05f716a4b49584f84
fef09b0aa37cbdb6a8f60a6bd8b473a7e5bffdc7fd2e952444f781574abccf64
Table 4: Linux/Unix Akira Ransomware Executable and Linkable Format (ELF) Samples
Hash (SHA-256)
e1321a4b2b104f31aceaf4b19c5559e40ba35b73a754d3ae13d8e90c53146c0f
74f497088b49b745e6377b32ed5d9dfaef3c84c7c0bb50fabf30363ad2e0bfb1
3d2b58ef6df743ce58669d7387ff94740ceb0122c4fc1c4ffd81af00e72e60a4
Table 5a: Commands Affiliated with Akira Ransomware
Persistence and Discovery
nltest /dclist: [T1018]
nltest /DOMAIN_TRUSTS [T1482]
net group “Domain admins” /dom [T1069.002]
net localgroup “Administrators” /dom [T1069.001]
tasklist [T1057]
rundll32.exe c:\Windows\System32\comsvcs.dll, MiniDump ((Get-Process lsass).Id) C:\windows\temp\lsass.dmp full [T1003.001]
Table 5b: Commands Affiliated with Akira Ransomware
Credential Access

cmd.exe /Q /c esentutl.exe /y

"C:\Users\<username>\AppData\Roaming\Mozilla\Firefox\Profiles\<firefox_profile_id>.default-release\key4.db" /d

"C:\Users\<username>\AppData\Roaming\Mozilla\Firefox\Profiles\<firefox_profile_id>.default-release\key4.db.tmp”

Note: Used for accessing Firefox data.

cmd.exe /Q /c esentutl.exe /y

"C:\Users\<username>\AppData\Local\Google\Chrome\User Data\Default\Login Data" /d

"C:\Users\<username>\AppData\Local\Google\Chrome\User Data\Default\Login Data.tmp”

Note: Used for accessing Google Chrome data.

Table 5c: Commands Affiliated with Akira Ransomware
Impact
powershell.exe -Command "Get-WmiObject Win32_Shadowcopy | Remove-WmiObject" [T1490]

MITRE ATT&CK TACTICS AND TECHNIQUES

See Tables 6 -14 for all referenced Akira threat actor tactics and techniques for enterprise environments in this advisory. For assistance with mapping malicious cyber activity to the MITRE ATT&CK framework, see CISA and MITRE ATT&CK’s Best Practices for MITRE ATT&CK Mapping and CISA’s Decider Tool.

Table 6: Initial Access
Technique Title ID Use
Valid Accounts T1078 Akira threat actors obtain and abuse credentials of existing accounts as a means of gaining initial access.
Exploit Public Facing Application T1190 Akira threat actors exploit vulnerabilities in internet-facing systems to gain access to systems.
External Remote Services T1133 Akira threat actors have used remote access services, such as RDP/VPN connection to gain initial access.
Phishing: Spearphishing Attachment  T1566.001 Akira threat actors use phishing emails with malicious attachments to gain access to networks.
Phishing: Spearphishing Link  T1566.002 Akira threat actors use phishing emails with malicious links to gain access to networks. 
Table 7: Credential Access
Technique Title ID Use
OS Credential Dumping T1003 Akira threat actors use tools like Mimikatz and LaZagne to dump credentials.

OS Credential Dumping:

LSASS Memory

T1003.001 Akira threat actors attempt to access credential material stored in the process memory of the LSASS.
Table 8: Discovery
Technique Title ID Use
System Network Configuration Discovery  T1016 Akira threat actors use tools to scan systems and identify services running on remote hosts and local network infrastructure.
System Information Discovery T1082 Akira threat actors use tools like PCHunter64 to acquire detailed process and system information.
Domain Trust Discovery T1482 Akira threat actors use the net Windows command to enumerate domain information.
Process Discovery T1057 Akira threat actors use the Tasklist utility to obtain details on running processes via PowerShell.
Permission Groups Discovery: Local Groups T1069.001 Akira threat actors use the net localgroup /dom to find local system groups and permission settings.
Permission Groups Discovery: Domain Groups  T1069.002 Akira threat actors use the net group /domain command to attempt to find domain level groups and permission settings.
Remote System Discovery T1018 Akira threat actors use nltest / dclist to amass a listing of other systems by IP address, hostname, or other logical identifiers on a network.
Table 9: Persistence
Technique Title ID Use
Create Account: Domain Account T1136.002 Akira threat actors attempt to abuse the functions of domain controllers by creating new domain accounts to establish persistence.
Table 10: Defense Evasion
Technique Title ID Use
Impair Defenses: Disable or Modify Tools T1562.001 Akira threat actors use BYOVD attacks to disable antivirus software.
Table 11: Command and Control
Technique Title ID Use
Remote Access Software T1219 Akira threat actors use legitimate desktop support software like AnyDesk to obtain remote access to victim systems.
Proxy T1090 Akira threat actors utilized Ngrok to create a secure tunnel to servers that aided in exfiltration of data. 
Table 12: Collection
Technique Title ID Use
Archive Collected Data: Archive via Utility T1560.001 Akira threat actors use tools like WinRAR to compress files.
Table 13: Exfiltration
Technique Title ID Use
Exfiltration Over Alternative Protocol T1048 Akira threat actors use file transfer tools like WinSCP to transfer data.
Transfer Data to Cloud Account T1537 Akira threat actors use tools like CloudZilla to exfiltrate data to a cloud account and connect to exfil servers they control.
Exfiltration Over Web Service: Exfiltration to Cloud Storage T1567.002 Akira threat actors leveraged RClone to sync files with cloud storage services to exfiltrate data. 
Table 14: Impact
Technique Title ID Use
Date Encrypted for Impact T1486 Akira threat actors encrypt data on target systems to interrupt availability to system and network resources.
Inhibit System Recovery T1490 Akira threat actors delete volume shadow copies on Windows systems.
Financial Theft T1657 Akira threat actors use a double-extortion model for financial gain.

MITIGATIONS

Network Defenders

The FBI, CISA, EC3, and NCSC-NL recommend organizations apply the following mitigations to limit potential adversarial use of common system and network discovery techniques, and to reduce the risk of compromise by Akira ransomware. These mitigations align with the Cross-Sector Cybersecurity Performance Goals (CPGs) developed by CISA and the National Institute of Standards and Technology (NIST). The CPGs provide a minimum set of practices and protections that CISA and NIST recommend all organizations implement. CISA and NIST based the CPGs on existing cybersecurity frameworks and guidance to protect against the most common and impactful threats and TTPs. Visit CISA’s Cross-Sector Cybersecurity Performance Goals for more information on the CPGs, including additional recommended baseline protections.

  • Implement a recovery plan to maintain and retain multiple copies of sensitive or proprietary data and servers in a physically separate, segmented, and secure location (e.g., hard drive, storage device, the cloud) [CPG 2.F, 2.R, 2.S].
  • Require all accounts with password logins (e.g., service accounts, admin accounts, and domain admin accounts) to comply with NIST’s standards. In particular, require employees to use long passwords and consider not requiring recurring password changes, as these can weaken security [CPG 2.C].
  • Require multifactor authentication for all services to the extent possible, particularly for webmail, virtual private networks, and accounts that access critical systems [CPG 2.H].
  • Keep all operating systems, software, and firmware up to date. Timely patching is one of the most efficient and cost effective steps an organization can take to minimize its exposure to cybersecurity threats. Prioritize patching known exploited vulnerabilities in internet-facing systems. [CPG 1.E].
  • Segment networks to prevent the spread of ransomware. Network segmentation can help prevent the spread of ransomware by controlling traffic flows between—and access to—various subnetworks and by restricting adversary lateral movement [CPG 2.F].
  • Identify, detect, and investigate abnormal activity and potential traversal of the indicated ransomware with a networking monitoring tool. To aid in detecting the ransomware, implement a tool that logs and reports all network traffic, including lateral movement activity on a network. Endpoint detection and response (EDR) tools are particularly useful for detecting lateral connections as they have insight into common and uncommon network connections for each host [CPG 3.A].
  • Filter network traffic by preventing unknown or untrusted origins from accessing remote services on internal systems. This prevents threat actors from directly connecting to remote access services that they have established for persistence.
  • Install, regularly update, and enable real time detection for antivirus software on all hosts.
  • Review domain controllers, servers, workstations, and active directories for new and/or unrecognized accounts [CPG 1.A, 2.O].
  • Audit user accounts with administrative privileges and configure access controls according to the principle of least privilege [CPG 2.E].
  • Disable unused ports [CPG 2.V].
  • Consider adding an email banner to emails received from outside of your organization [CPG 2.M].
  • Disable hyperlinks in received emails.
  • Implement time-based access for accounts set at the admin level and higher. For example, the Just-in-Time (JIT) access method provisions privileged access when needed and can support enforcement of the principle of least privilege (as well as the Zero Trust model). This is a process where a network-wide policy is set in place to automatically disable admin accounts at the Active Directory level when the account is not in direct need. Individual users may submit their requests through an automated process that grants them access to a specified system for a set timeframe when they need to support the completion of a certain task.
  • Disable command-line and scripting activities and permissions. Privilege escalation and lateral movement often depend on software utilities running from the command line. If threat actors are not able to run these tools, they will have difficulty escalating privileges and/or moving laterally [CPG 2.E, 2.N].
  • Maintain offline backups of data, and regularly maintain backup and restoration [CPG 2.R]. By instituting this practice, the organization helps ensure they will not be severely interrupted, and/or only have irretrievable data. 
  • Ensure all backup data is encrypted, immutable (i.e., cannot be altered or deleted), and covers the entire organization’s data infrastructure [CPG 2.K, 2.L, 2.R].

VALIDATE SECURITY CONTROLS

In addition to applying mitigations, the FBI, CISA, EC3, and NCSC-NL recommend exercising, testing, and validating your organization’s security program against the threat behaviors mapped to the MITRE ATT&CK for Enterprise framework in this advisory. The FBI, CISA, EC3 and NCSC-NL recommend testing your existing security controls inventory to assess how they perform against the ATT&CK techniques described in this advisory.

To get started:

  1. Select an ATT&CK technique described in this advisory (see Tables 6 -14).
  2. Align your security technologies against the technique.
  3. Test your technologies against the technique.
  4. Analyze your detection and prevention technologies’ performance.
  5. Repeat the process for all security technologies to obtain a set of comprehensive performance data.
  6. Tune your security program, including people, processes, and technologies, based on the data generated by this process.

The FBI, CISA, EC3, and NCSC-NL recommend continually testing your security program, at scale, in a production environment to ensure optimal performance against the MITRE ATT&CK techniques identified in this advisory.

RESOURCES

REFERENCES

  1. Fortinet: Ransomware Roundup - Akira
  2. Cisco: Akira Ransomware Targeting VPNs without MFA
  3. Truesec: Indications of Akira Ransomware Group Actively Exploiting Cisco AnyConnect CVE-2020-3259
  4. TrendMicro: Akira Ransomware Spotlight
  5. CrowdStrike: What is a Kerberoasting Attack?
  6. Sophos: Akira, again: The ransomware that keeps on taking
  7. Sophos: Akira Ransomware is “bringin’ 1988 back”

REPORTING

Your organization has no obligation to respond or provide information back to the FBI in response to this joint CSA. If, after reviewing the information provided, your organization decides to provide information to the FBI, reporting must be consistent with applicable state and federal laws.

The FBI is interested in any information that can be shared, to include boundary logs showing communication to and from foreign IP addresses, a sample ransom note, communications with Akira threat actors, Bitcoin wallet information, decryptor files, and/or a benign sample of an encrypted file.

Additional details of interest include: a targeted company point of contact, status and scope of infection, estimated loss, operational impact, transaction IDs, date of infection, date detected, initial attack vector, and host- and network-based indicators.

The FBI, CISA, EC3, and NCSC-NL do not encourage paying ransom as payment does not guarantee victim files will be recovered. Furthermore, payment may also embolden adversaries to target additional organizations, encourage other criminal actors to engage in the distribution of ransomware, and/or fund illicit activities. Regardless of whether you or your organization have decided to pay the ransom, the FBI and CISA urge you to promptly report ransomware incidents to the FBI’s Internet Crime Complain Center (IC3), a local FBI Field Office, or CISA via the agency’s Incident Reporting System or its 24/7 Operations Center (report@cisa.gov or (888) 282-0870).

DISCLAIMER

The information in this report is being provided “as is” for informational purposes only. The FBI, CISA, EC3, and NCSC-NL do not endorse any commercial entity, product, company, or service, including any entities, products, or services linked within this document. Any reference to specific commercial products, processes, or services by service mark, trademark, manufacturer, or otherwise, does not constitute or imply endorsement, recommendation, or favoring by the FBI or CISA.

ACKNOWLEDGEMENTS

Cisco, Sophos, and Fortinet contributed to this advisory.

VERSION HISTORY

April 18, 2024: Initial version.

CISA and Partners Release Advisory on Akira Ransomware

By: CISA
18 April 2024 at 08:00

Today, CISA, the Federal Bureau of Investigation (FBI), Europol’s European Cybercrime Centre (EC3), and the Netherlands’ National Cyber Security Centre (NCSC-NL) released a joint Cybersecurity Advisory (CSA), #StopRansomware: Akira Ransomware, to disseminate known Akira ransomware tactics, techniques, and procedures (TTPs) and indicators of compromise (IOCs) identified through FBI investigations as recently as February 2024.

Evolving from an initial focus on Windows systems to a Linux variant targeting VMware ESXi virtual machines, Akira threat actors began deploying Megazord (a Rust-based code) and Akira (written in C++), including Akira_v2 (also Rust-based) in August 2023. Akira ransomware has impacted a wide range of businesses and critical infrastructure entities in North America, Europe, and Australia and claimed approximately $42 million (USD) in ransomware proceeds.

CISA and partners encourage critical infrastructure organizations to review and implement the mitigations provided in the joint CSA to reduce the likelihood and impact of Akira and other ransomware incidents. For more information, see CISA’s #StopRansomware webpage and the updated #StopRansomware Guide.

Oracle Releases Critical Patch Update Advisory for April 2024

By: CISA
18 April 2024 at 08:00

Oracle released its quarterly Critical Patch Update Advisory for April 2024 to address vulnerabilities in multiple products. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 

Users and administrators are encouraged to review the following Critical Patch Update Advisory and apply the necessary updates:  

Unitronics Vision Legacy series

By: CISA
18 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Unitronics
  • Equipment: Vision Legacy series
  • Vulnerability: Storing Passwords in a Recoverable Format

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to log in to the Remote HMI feature, where the PLC may be factory reset, stopped, and restarted.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Unitronics Vision Legacy series PLCs are affected:

  • Vision 230: All versions
  • Vision 280: All versions
  • Vision 290: All versions
  • Vision 530: All versions
  • Vision 120: All versions

3.2 Vulnerability Overview

3.2.1 Storing Passwords in a Recoverable Format CWE-257

Unitronics Vision Legacy series PLCs allow a remote, unauthenticated individual to retrieve the 'Information Mode' password in plaintext.

CVE-2024-1480 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2024-1480. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Water and Wastewater
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Israel

3.4 RESEARCHER

Reid Wightman of Dragos reported this vulnerability to CISA.

4. MITIGATIONS

Dragos recommends users to restrict access to the PLC on TCP/20256 by either changing the default programmer port, or apply a multi-factor VPN to protect the service from remote access.

Unitronics has not responded to requests to work with CISA to mitigate this vulnerability. Please contact Unitronics customer support for more information.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 18, 2024: Initial Publication

CISA Releases Three Industrial Control Systems Advisories

By: CISA
18 April 2024 at 08:00

CISA released three Industrial Control Systems (ICS) advisories on April 18, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Rockwell Automation ControlLogix and GuardLogix

By: CISA
16 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 9.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: ControlLogix 5580, GuardLogix 5580, CompactLogix 5380, 1756-EN4TR
  • Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to cause a major nonrecoverable fault (MNRF) resulting in the product to become unavailable.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Rockwell Automation ControlLogix and GuardLogix, programmable logic controllers, are affected:

  • ControlLogix 5580: Version V35.011
  • GuardLogix 5580: Version V35.011
  • CompactLogix 5380: Version V35.011
  • 1756-EN4TR: Version V5.001

3.2 Vulnerability Overview

3.2.1 IMPROPER INPUT VALIDATION CWE-20

A specific malformed fragmented packet type (fragmented packets may be generated automatically by devices that send large amounts of data) can cause a major nonrecoverable fault (MNRF). If exploited, the affected product will become unavailable and require a manual restart to recover it. Additionally, a MNRF could result in a loss of view and/or control of connected devices.

CVE-2024-3493 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-3493. A base score of 9.2 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation has released product updates addressing this vulnerability:

  • ControlLogix 5580: Update to version V35.013 or V36.011
  • GuardLogix 5580: Update to version V35.013 or V36.011
  • CompactLogix 5380: Update to version V35.013 or V36.011
  • 1756-EN4TR: Update to version V6.001

For more information, see Rockwell Automation's security advisory (Login required).

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 16, 2024: Initial Publication

Measuresoft ScadaPro

By: CISA
16 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 6.8
  • ATTENTION: Low attack complexity
  • Vendor: Measuresoft
  • Equipment: ScadaPro
  • Vulnerability: Improper Access Control

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to escalate their privileges from unprivileged to SYSTEM privileges.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of ScadaPro, a supervisory control and data acquisition (SCADA) system, are affected:

  • ScadaPro: version 6.9.0.0

3.2 Vulnerability Overview

3.2.1 IMPROPER ACCESS CONTROL CWE-284

The entire parent directory - C:\ScadaPro and its sub-directories and files are configured by default to allow user, including unprivileged users, to write or overwrite files.

CVE-2024-3746 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2024-3746. A base score of 6.8 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy, Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Ireland

3.4 RESEARCHER

Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA.

4. MITIGATIONS

Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Exercise principles of least privilege.
  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

This vulnerability is not exploitable remotely. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 16, 2024: Initial Publication

RoboDK RoboDK

By: CISA
16 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 3.3
  • ATTENTION: Low attack complexity
  • Vendor: RoboDK
  • Equipment: RoboDK
  • Vulnerability: Heap-based Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could result in an attacker crashing the program through heap-based buffer overflow.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of RoboDK, a robotics development software, are affected:

  • RoboDK: RoboDK v5.5.4 (Windows 64 bit)

3.2 Vulnerability Overview

3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122

The affected product is vulnerable to heap-based buffer overflow while processing a specific project file. The resulting memory corruption may crash the application.

CVE-2024-0257 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Canada

3.4 RESEARCHER

Hank Chen, while working with TXOne Networks, reported this vulnerability to CISA.

4. MITIGATIONS

RoboDK did not respond to CISA's attempts at coordination. Users of RoboDK are encouraged to contact RoboDK and keep their systems up to date.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • April 16, 2024: Initial Publication

Electrolink FM/DAB/TV Transmitter

By: CISA
16 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.8
  • ATTENTION: Exploitable remotely/low attack complexity/public exploits are available
  • Vendor: Electrolink
  • Equipment: FM/DAB/TV Transmitter
  • Vulnerabilities: Authentication Bypass by Assumed-Immutable Data, Reliance on Cookies without Validation and Integrity Checking, Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to obtain full system access, keep the device from transmitting, escalate privileges, change credentials, and execute arbitrary code.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Electrolink transmitters are affected:

  • 10W, 100W, 250W, Compact DAB Transmitter
  • 500W, 1kW, 2kW Medium DAB Transmitter
  • 2.5kW, 3kW, 4kW, 5kW High Power DAB Transmitter
  • 100W, 500W, 1kW, 2kW Compact FM Transmitter
  • 3kW, 5kW, 10kW, 15kW, 20kW, 30kW Modular FM Transmitter
  • 15W - 40kW Digital FM Transmitter
  • BI, BIII VHF TV Transmitter
  • 10W - 5kW UHF TV Transmitter

3.2 Vulnerability Overview

3.2.1 Authentication Bypass by Assumed-Immutable Data CWE-302

Electrolink transmitters are vulnerable to an authentication bypass vulnerability affecting the login cookie. An attacker can set an arbitrary value except 'NO' to the login cookie and have full system access.

CVE-2024-3741 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has been calculated for CVE-2024-3741. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.2 Authentication Bypass by Assumed-Immutable Data CWE-302

The application is vulnerable to an unauthenticated parameter manipulation that allows an attacker to set the credentials to blank giving her access to the admin panel. Also vulnerable to account takeover and arbitrary password change.

CVE-2024-22179 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has been calculated for CVE-2024-22179. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.3 Reliance on Cookies without Validation and Integrity Checking CWE-565

The application suffers from a privilege escalation vulnerability. An attacker logged in as guest can escalate his privileges by poisoning the cookie to become administrator.

CVE-2024-22186 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

A CVSS v4 score has been calculated for CVE-2024-22186. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.4 Reliance on Cookies without Validation and Integrity Checking CWE-565

The device allows an unauthenticated attacker to bypass authentication and modify the cookie to reveal hidden pages that allows more critical operations to the transmitter.

CVE-2024-21872 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has been calculated for CVE-2024-21872. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.2.5 Missing Authentication for Critical Function CWE-306

An unauthenticated attacker can reset the board and stop transmitter operations by sending a specially-crafted GET request to the command.cgi gateway, resulting in a denial-of-service scenario.

CVE-2024-21846 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

A CVSS v4 score has been calculated for CVE-2024-21846. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.2.6 Missing Authentication for Critical Function CWE-306

The devices allow access to an unprotected endpoint that allows MPFS file system binary image upload without authentication. The MPFS2 file system module provides a light-weight read-only file system that can be stored in external EEPROM, external serial flash, or internal flash program memory. This file system serves as the basis for the HTTP2 web server module, but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code.

CVE-2024-1491 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has been calculated for CVE-2024-1491. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.7 Cleartext Storage of Sensitive Information CWE-312

Electrolink transmitters store credentials in clear-text. Use of these credentials could allow an attacker to access the system.

CVE-2024-3742 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has been calculated for CVE-2024-3742. A base score of 8.7 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Communications Sector
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Italy

3.4 RESEARCHER

Gjoko Krstic publicly reported these vulnerabilities on the internet after an unsuccessful attempt to contact Electrolink directly.

4. MITIGATIONS

Electrolink has not responded to requests to work with CISA to mitigate these vulnerabilities. Users of the affected products are encouraged to contact Electrolink for additional information.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 16, 2024: Initial Publication

CISA Releases Four Industrial Control Systems Advisories

By: CISA
16 April 2024 at 08:00

CISA released four Industrial Control Systems (ICS) advisories on April 16, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Joint Guidance on Deploying AI Systems Securely

By: CISA
15 April 2024 at 08:00

Today, the National Security Agency’s Artificial Intelligence Security Center (NSA AISC) published the joint Cybersecurity Information Sheet Deploying AI Systems Securely in collaboration with CISA, the Federal Bureau of Investigation (FBI), the Australian Signals Directorate’s Australian Cyber Security Centre (ASD ACSC), the Canadian Centre for Cyber Security (CCCS), the New Zealand National Cyber Security Centre (NCSC-NZ), and the United Kingdom’s National Cyber Security Centre (NCSC-UK).

The guidance provides best practices for deploying and operating externally developed artificial intelligence (AI) systems and aims to:

  • Improve the confidentiality, integrity, and availability of AI systems. 
  • Ensure there are appropriate mitigations for known vulnerabilities in AI systems.
  • Provide methodologies and controls to protect, detect, and respond to malicious activity against AI systems and related data and services.

CISA encourages organizations deploying and operating externally developed AI systems to review and apply this guidance as applicable. CISA also encourages organizations to review previously published joint guidance on securing AI systems: Guidelines for secure AI system development and Engaging with Artificial Intelligence. For more CISA information and guidance on securing AI systems, see cisa.gov/ai.

 

Palo Alto Networks Releases Guidance for Vulnerability in PAN-OS, CVE-2024-3400

By: CISA
12 April 2024 at 08:00

Palo Alto Networks has released workaround guidance for a command injection vulnerability (CVE-2024-3400) affecting PAN-OS versions 10.2, 11.0, and 11.1. Palo Alto Networks has reported active exploitation of this vulnerability in the wild. 

CISA encourages users and administrators to review the Palo Alto Networks Security Advisory, apply the current mitigations, and update the affected software when Palo Alto Networks makes the fixes available. 

CISA has also added this vulnerability to its Known Exploited Vulnerabilities Catalog.

Additional resources:

Citrix Releases Security Updates for XenServer and Citrix Hypervisor

By: CISA
12 April 2024 at 08:00

Citrix released security updates to address multiple vulnerabilities in XenServer and Citrix Hypervisor. A cyber threat actor could exploit one of these vulnerabilities to take control of an affected system. 

CISA encourages users and administrators to review and apply the necessary updates: 

CISA Adds One Known Exploited Vulnerability to Catalog

By: CISA
12 April 2024 at 08:00

CISA has added one new vulnerability to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2024-3400 Palo Alto Networks PAN-OS Command Injection Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise.

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Juniper Releases Security Bulletin for Multiple Juniper Products

By: CISA
12 April 2024 at 08:00

Juniper has released security updates to address multiple vulnerabilities in Junos OS, Junos OS Evolved, Paragon Active Assurance and Junos OS: EX4300 Series. A cyber threat actor could exploit some of these vulnerabilities to cause a denial-of-service condition.

Users and administrators are encouraged to review Juniper’s Support Portal and apply the necessary updates.

CISA Adds Two Known Exploited Vulnerabilities to Catalog

By: CISA
11 April 2024 at 08:00

CISA has added two new vulnerabilities to its Known Exploited Vulnerabilities Catalog, based on evidence of active exploitation.

  • CVE-2024-3272 D-Link Multiple NAS Devices Use of Hard-Coded Credentials Vulnerability
  • CVE-2024-3273 D-Link Multiple NAS Devices Command Injection Vulnerability

These types of vulnerabilities are frequent attack vectors for malicious cyber actors and pose significant risks to the federal enterprise. 

Binding Operational Directive (BOD) 22-01: Reducing the Significant Risk of Known Exploited Vulnerabilities established the Known Exploited Vulnerabilities Catalog as a living list of known Common Vulnerabilities and Exposures (CVEs) that carry significant risk to the federal enterprise. BOD 22-01 requires Federal Civilian Executive Branch (FCEB) agencies to remediate identified vulnerabilities by the due date to protect FCEB networks against active threats. See the BOD 22-01 Fact Sheet for more information.

Although BOD 22-01 only applies to FCEB agencies, CISA strongly urges all organizations to reduce their exposure to cyberattacks by prioritizing timely remediation of Catalog vulnerabilities as part of their vulnerability management practice. CISA will continue to add vulnerabilities to the catalog that meet the specified criteria.

Siemens Telecontrol Server Basic

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 8.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: Telecontrol Server Basic
  • Vulnerabilities: Inadequate Encryption Strength, Double Free, Integer Overflow or Wraparound, External Control of File Name or Path, Path Traversal, Improper Input Validation, Missing Encryption of Sensitive Data, Use After Free, Improper Certificate Validation, Inefficient Regular Expression Complexity, Improper Check for Unusual or Exceptional Conditions, NULL Pointer Dereference, Improper Restriction of Operations within the Bounds of a Memory Buffer

2. RISK EVALUATION

Successful exploitation of this vulnerability could

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

Siemens reports that the following products are affected:

  • Siemens TeleControl Server Basic V3: versions prior to V3.1.2

3.2 Vulnerability Overview

3.2.1 INADEQUATE ENCRYPTION STRENGTH CWE-326

A timing-based side channel exists in the OpenSSL RSA decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection.

CVE-2022-4304 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.2.2 DOUBLE FREE CWE-415

The function PEM_read_bio_ex() reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case PEM_read_bio_ex() will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial-of-service attack. The functions PEM_read_bio() and PEM_read() are simple wrappers around PEM_read_bio_ex() and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including PEM_X509_INFO_read_bio_ex() and SSL_CTX_use_serverinfo_file() which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if PEM_read_bio_ex() returns a failure code. These locations include the PEM_read_bio_TYPE() functions as well as the decoders introduced in OpenSSL 3.0. The OpenSSL asn1parse command line application is also impacted by this issue.

CVE-2022-4450 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.3 INTEGER OVERFLOW OR WRAPAROUND CWE-190

An issue was discovered in libxml2 before 2.10.3. When parsing a multi-gigabyte XML document with the XML_PARSE_HUGE parser option enabled, several integer counters can overflow. This results in an attempt to access an array at a negative 2GB offset, typically leading to a segmentation fault.

CVE-2022-40303 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.4 DOUBLE FREE CWE-415

An issue was discovered in libxml2 before 2.10.3. Certain invalid XML entity definitions can corrupt a hash table key, potentially leading to subsequent logic errors. In one case, a double free can be provoked.

CVE-2022-40304 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.5 EXTERNAL CONTROL OF FILE NAME OR PATH CWE-73

The affected components allow to rename license files with user chosen input without authentication. This could allow an unauthenticated remote attacker to rename and move files as SYSTEM user.

CVE-2022-43513 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L).

3.2.6 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22

The affected component does not correctly validate the root path on folder related operations, allowing to modify files and folders outside the intended root directory. This could allow an unauthenticated remote attacker to execute file operations of files outside of the specified root folder. Chained with CVE-2022-43513 this could allow remote code execution.

CVE-2022-43514 has been assigned to this vulnerability. A CVSS v3 base score of 7.7 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L).

3.2.7 IMPROPER INPUT VALIDATION CWE-20

OPC Foundation Local Discovery Server (LDS) in affected products uses a hard-coded file path to a configuration file. This allows a normal user to create a malicious file that is loaded by LDS (running as a high-privilege user).

CVE-2022-44725 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.8 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

SQLite through 3.40.0, when relying on --safe for execution of an untrusted CLI script, does not properly implement the azProhibitedFunctions protection mechanism, and instead allows UDF functions such as WRITEFILE.

CVE-2022-46908 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L).

3.2.9 USE AFTER FREE CWE-416

The public API function BIO_new_NDEF is a helper function used for streaming ASN.1 data via a BIO. It is primarily used internally to OpenSSL to support the SMIME, CMS and PKCS7 streaming capabilities, but may also be called directly by end user applications. The function receives a BIO from the caller, prepends a new BIO_f_asn1 filter BIO onto the front of it to form a BIO chain, and then returns the new head of the BIO chain to the caller. Under certain conditions, for example if a CMS recipient public key is invalid, the new filter BIO is freed and the function returns a NULL result indicating a failure. However, in this case, the BIO chain is not properly cleaned up and the BIO passed by the caller still retains internal pointers to the previously freed filter BIO. If the caller then goes on to call BIO_pop() on the BIO then a use-after-free will occur. This will most likely result in a crash. This scenario occurs directly in the internal function B64_write_ASN1() which may cause BIO_new_NDEF() to be called and will subsequently call BIO_pop() on the BIO. This internal function is in turn called by the public API functions PEM_write_bio_ASN1_stream, PEM_write_bio_CMS_stream, PEM_write_bio_PKCS7_stream, SMIME_write_ASN1, SMIME_write_CMS and SMIME_write_PKCS7. Other public API functions that may be impacted by this include i2d_ASN1_bio_stream, BIO_new_CMS, BIO_new_PKCS7, i2d_CMS_bio_stream and i2d_PKCS7_bio_stream. The OpenSSL cms and smime command line applications are similarly affected.

CVE-2023-0215 has been assigned to this vulnerability. A CVSS v3 base score of 5.9 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.10 IMPROPER INPUT VALIDATION CWE-20

There is a type confusion vulnerability relating to X.400 address processing inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. This field is subsequently interpreted by the OpenSSL function GENERAL_NAME_cmp as an ASN1_TYPE rather than an ASN1_STRING. When CRL checking is enabled (i.e. the application sets the X509_V_FLAG_CRL_CHECK flag), this vulnerability may allow an attacker to pass arbitrary pointers to a memcmp call, enabling them to read memory contents or enact a denial of service. In most cases, the attack requires the attacker to provide both the certificate chain and CRL, neither of which need to have a valid signature. If the attacker only controls one of these inputs, the other input must already contain an X.400 address as a CRL distribution point, which is uncommon. As such, this vulnerability is most likely to only affect applications which have implemented their own functionality for retrieving CRLs over a network.

CVE-2023-0286 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:H).

3.2.11 IMPROPER CERTIFICATE VALIDATION CWE-295

A security vulnerability has been identified in all supported versions of OpenSSL related to the verification of X.509 certificate chains that include policy constraints. Attackers may be able to exploit this vulnerability by creating a malicious certificate chain that triggers exponential use of computational resources, leading to a denial-of-service attack on affected systems. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.

CVE-2023-0464 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.12 IMPROPER CERTIFICATE VALIDATION CWE-295

Applications that use a non-default option when verifying certificates may be vulnerable to an attack from a malicious certificate authority to circumvent certain checks. Invalid certificate policies in leaf certificates are silently ignored by OpenSSL and other certificate policy checks are skipped for that certificate. A malicious certificate authority could use this to deliberately assert invalid certificate policies in order to circumvent policy checking on the certificate altogether. Policy processing is disabled by default but can be enabled by passing the -policy argument to the command line utilities or by calling the X509_VERIFY_PARAM_set1_policies() function.

CVE-2023-0465 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

3.2.13 IMPROPER CERTIFICATE VALIDATION CWE-295

The function X509_VERIFY_PARAM_add0_policy() is documented to implicitly enable the certificate policy check when doing certificate verification. However the implementation of the function does not enable the check which allows certificates with invalid or incorrect policies to pass the certificate verification. As suddenly enabling the policy check could break existing deployments it was decided to keep the existing behavior of the X509_VERIFY_PARAM_add0_policy() function. Instead the applications that require OpenSSL to perform certificate policy check need to use X509_VERIFY_PARAM_set1_policies() or explicitly enable the policy check by calling X509_VERIFY_PARAM_set_flags() with the X509_V_FLAG_POLICY_CHECK flag argument. Certificate policy checks are disabled by default in OpenSSL and are not commonly used by applications.

CVE-2023-0466 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N).

3.2.14 INEFFICIENT REGULAR EXPRESSION COMPLEXITY CWE-1333

Checking excessively long DH keys or parameters may be very slow. Applications that use the functions DH_check(), DH_check_ex() or EVP_PKEY_param_check() to check a DH key or DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a denial of service. The function DH_check() performs various checks on DH parameters. One of those checks confirms that the modulus ('p' parameter) is not too large. Trying to use a very large modulus is slow and OpenSSL will not normally use a modulus which is over 10,000 bits in length. However the DH_check() function checks numerous aspects of the key or parameters that have been supplied. Some of those checks use the supplied modulus value even if it has already been found to be too large. An application that calls DH_check() and supplies a key or parameters obtained from an untrusted source could be vulernable to a denial of service attack. The function DH_check() is itself called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_ex() and EVP_PKEY_param_check(). Also vulnerable are the OpenSSL dhparam and pkeyparam command line applications when using the '-check' option. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-3446 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.15 IMPROPER INPUT VALIDATION CWE-20

The POLY1305 MAC (message authentication code) implementation contains a bug that might corrupt the internal state of applications on the Windows 64 platform when running on newer X86_64 processors supporting the AVX512-IFMA instructions. If an application that uses the OpenSSL library an attacker can influence whether the POLY1305 MAC algorithm is used, the application state might be corrupted with various application dependent consequences. The POLY1305 MAC (message authentication code) implementation in OpenSSL does not save the contents of non-volatile XMM registers on Windows 64 platform when calculating the MAC of data larger than 64 bytes. Before returning to the caller, all the XMM registers are set to zero rather than restoring their previous content. The vulnerable code is used only on newer x86_64 processors supporting the AVX512-IFMA instructions. The consequences of this kind of internal application state corruption can be various - from no consequences, if the calling application does not depend on the contents of non-volatile XMM registers at all, to the worst consequences, where the attacker could get complete control of the application process. However given the contents of the registers are just zeroized so the attacker cannot put arbitrary values inside, the most likely consequence, if any, would be an incorrect result of some application dependent calculations or a crash leading to a denial of service. The POLY1305 MAC algorithm is most frequently used as part of the CHACHA20-POLY1305 AEAD (authenticated encryption with associated data) algorithm. The most common usage of this AEAD cipher is with TLS protocol versions 1.2 and 1.3 and a malicious client can influence whether this AEAD cipher is used by the server. This implies that server applications using OpenSSL can be potentially impacted. However we are currently not aware of any concrete application that would be affected by this issue therefore we consider this a low severity security issue. As a workaround the AVX512-IFMA instructions support can be disabled at runtime by setting the environment variable OPENSSL_ia32cap: OPENSSL_ia32cap=:~0x200000 The FIPS provider is not affected by this issue.

CVE-2023-4807 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.16 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a denial of service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn't make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn't check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a denial of service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the "-pubcheck" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-5678 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.17 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server remote code execution vulnerability.

CVE-2023-21528 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.18 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server Integration Service (VS extension) remote code execution vulnerability.

CVE-2023-21568 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.2.19 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-21704 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.20 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server remote code execution vulnerability.

CVE-2023-21705 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.21 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server remote code execution vulnerability.

CVE-2023-21713 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.22 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-21718 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.23 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server remote code execution vulnerability.

CVE-2023-23384 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L).

3.2.24 NULL POINTER DEREFERENCE CWE-476

In libxml2 before 2.10.4, parsing of certain invalid XSD schemas can lead to a NULL pointer dereference and subsequently a segmentation fault. This occurs in xmlSchemaFixupComplexType in xmlschemas.c.

CVE-2023-28484 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.25 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC and OLE DB remote code execution vulnerability.

CVE-2023-29349 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.26 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-29356 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.27 DOUBLE FREE CWE-415

An issue was discovered in libxml2 before 2.10.4. When hashing empty dict strings in a crafted XML document, xmlDictComputeFastKey in dict.c can produce non-deterministic values, leading to various logic and memory errors, such as a double free. This behavior occurs because there is an attempt to use the first byte of an empty string, and any value is possible (not solely the '\0' value).

CVE-2023-29469 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.2.28 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-32025 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.29 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-32026 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.30 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-32027 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.31 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL OLE DB remote code execution vulnerability.

CVE-2023-32028 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.32 IMPROPER INPUT VALIDATION CWE-20

.NET, .NET Framework, and Visual Studio elevation of privilege vulnerability.

CVE-2023-36049 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:L).

3.2.33 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL OLE DB remote code execution vulnerability.

CVE-2023-36417 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.34 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-36420 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.35 IMPROPER INPUT VALIDATION CWE-20

ASP.NET security feature bypass vulnerability.

CVE-2023-36560 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.36 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL Server denial-of-service vulnerability.

CVE-2023-36728 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.37 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-36730 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.38 IMPROPER INPUT VALIDATION CWE-20

Microsoft ODBC Driver for SQL Server remote code execution vulnerability.

CVE-2023-36785 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.39 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

.NET Framework remote code execution vulnerability.

CVE-2023-36788 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.40 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

Visual Studio remote code execution vulnerability.

CVE-2023-36792 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.41 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

Visual Studio remote code execution vulnerability.

CVE-2023-36793 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.42 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

Visual Studio remote code execution vulnerability.

CVE-2023-36794 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.43 MISSING ENCRYPTION OF SENSITIVE DATA CWE-311

Visual Studio remote code execution vulnerability.

CVE-2023-36796 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.44 IMPROPER INPUT VALIDATION CWE-20

.NET Framework spoofing vulnerability.

CVE-2023-36873 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).

3.2.45 IMPROPER INPUT VALIDATION CWE-20

ASP.NET elevation of privilege vulnerability.

CVE-2023-36899 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.46 IMPROPER INPUT VALIDATION CWE-20

Microsoft SQL OLE DB remote code execution vulnerability.

CVE-2023-38169 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.2.47 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119

Xmlsoft Libxml2 v2.11.0 was discovered to contain an out-of-bounds read via the xmlSAX2StartElement() function at /libxml2/SAX2.c. This vulnerability allows attackers to cause a denial of service via supplying a crafted XML file. NOTE: the vendor's position is that the product does not support the legacy SAX1 interface with custom callbacks; there is a crash even without crafted input.

CVE-2023-39615 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy, Transportation Systems, Water and Wastewater Systems
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has released a new version for Telecontrol Server Basic that fixes multiple vulnerabilities:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-556635 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

CISA Issues Emergency Directive 24-02: Mitigating the Significant Risk from Nation-State Compromise of Microsoft Corporate Email System

By: CISA
11 April 2024 at 08:00

Today, CISA publicly issued Emergency Directive (ED) 24-02 to address the recent campaign by Russian state-sponsored cyber actor Midnight Blizzard to exfiltrate email correspondence of Federal Civilian Executive Branch (FCEB) agencies through a successful compromise of Microsoft corporate email accounts. This Directive rhttps://www.cisa.gov/news-events/directives/ed-24-02-mitigating-significant-risk-nation-state-compromise-microsoft-corporate-email-systemequires agencies to analyze the content of exfiltrated emails, reset compromised credentials, and take additional steps to secure privileged Microsoft Azure accounts.

While ED 24-02 requirements only apply to FCEB agencies, other organizations may also have been impacted by the exfiltration of Microsoft corporate email and are encouraged to contact their respective Microsoft account team for any additional questions or follow up. FCEB agencies and state and local government should utilize the distro MBFedResponse@Microsoft.com for any escalations and assistance with Microsoft. Regardless of direct impact, all organizations are strongly encouraged to apply stringent security measures, including strong passwords, multifactor authentication (MFA) and prohibited sharing of unprotected sensitive information via unsecure channels.

Siemens RUGGEDCOM APE1808 before V11.0.1

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 6.1
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808
  • Vulnerabilities: Network Amplification, Exposure of Sensitive System Information to an Unauthorized Control Sphere, External Control of File Name or Path, Cross-site Scripting, Insufficiently Protected Credentials, Externally Controlled Reference to a Resource in Another Sphere

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow a network-based attacker to conduct reflected and amplified TCP denial-of-service (RDoS) attacks.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens RUGGEDCOM APE1808, an application hosting platform, are affected:

  • Siemens RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW before V11.0.1

3.2 Vulnerability Overview

3.2.1 INSUFFICIENT CONTROL OF NETWORK MESSAGE VOLUME (NETWORK AMPLIFICATION) CWE-406

A PAN-OS URL filtering policy misconfiguration could allow a network-based attacker to conduct reflected and amplified TCP denial-of-service (DoS) attacks. The DoS attack would appear to originate from a Palo Alto Networks PA-Series (hardware), VM-Series (virtual) and CN-Series (container) firewall against an attacker-specified target. To be misused by an external attacker, the firewall configuration must have a URL filtering profile with one or more blocked categories assigned to a source zone that has an external facing interface. This configuration is not typical for URL filtering and, if set, is likely unintended by the administrator. If exploited, this issue would not impact the confidentiality, integrity, or availability of our products. However, the resulting denial-of-service (DoS) attack may help obfuscate the identity of the attacker and implicate the firewall as the source of the attack. We have taken prompt action to address this issue in our PAN-OS software. All software updates for this issue are expected to be released no later than the week of August 15, 2022. This issue does not impact Panorama M-Series or Panorama virtual appliances. This issue has been resolved for all Cloud NGFW and Prisma Access customers and no additional action is required from them.

CVE-2022-0028 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.2 EXPOSURE OF SENSITIVE SYSTEM INFORMATION TO AN UNAUTHORIZED CONTROL SPHERE CWE-497

A vulnerability in Palo Alto Networks PAN-OS software enables an authenticated administrator to expose the plaintext values of secrets stored in the device configuration and encrypted API keys.

CVE-2023-0005 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.1 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N).

3.2.3 EXTERNAL CONTROL OF FILE NAME OR PATH CWE-73

A file disclosure vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-write administrator with access to the web interface to export local files from the firewall through a race condition.

CVE-2023-0008 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N).

3.2.4 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79

A DOM-Based cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS software enables a remote attacker to execute a JavaScript payload in the context of an administrator's browser when they view a specifically crafted link to the PAN-OS web interface.

CVE-2023-6790 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-6790. A base score of 6.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N).

3.2.5 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522

A credential disclosure vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-only administrator to obtain the plaintext credentials of stored external system integrations such as LDAP, SCP, RADIUS, TACACS+, and SNMP from the web interface.

CVE-2023-6791 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

A CVSS v4 score has also been calculated for CVE-2023-6791. A base score of 6.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:H/SI:N/SA:N).

3.2.6 EXTERNALLY CONTROLLED REFERENCE TO A RESOURCE IN ANOTHER SPHERE CWE-610

A vulnerability exists in Palo Alto Networks PAN-OS software that enables an authenticated administrator with the privilege to commit a specifically created configuration to read local files and resources from the system.

CVE-2023-38046 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:L/A:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • RUGGEDCOM APE1808: Upgrade Palo Alto Networks Virtual NGFW V11.0.1. Contact Siemens customer support to receive patch and update information.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-822518 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this (these) vulnerability(ies), such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Siemens Parasolid

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.3
  • ATTENTION: Low Attack Complexity
  • Vendor: Siemens
  • Equipment: Parasolid
  • Vulnerabilities: Out-of-bounds Read, Allocation of Resources Without Limits or Throttling, NULL Pointer Dereference

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to execute code within the context of the current process.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • Siemens Parasolid V35.1: Versions prior to V35.1.254
  • Siemens Parasolid V36.0: Versions prior to V36.0.207
  • Siemens Parasolid V36.1: Versions prior to V36.1.147

3.2 Vulnerability Overview

3.2.1 OUT-OF-BOUNDS READ CWE-125

The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.

CVE-2024-26275 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

CVE-2024-26275 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N).

3.2.2 ALLOCATION OF RESOURCES WITHOUT LIMITS OR THROTTLING CWE-770

The affected application contains a stack exhaustion vulnerability while parsing a specially crafted X_T file. This could allow an attacker to cause denial of service condition.

CVE-2024-26276 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).

CVE-2024-26276 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been assigned; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.2.3 NULL POINTER DEREFERENCE CWE-476

The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition.

CVE-2024-26277 has been assigned to this vulnerability. A CVSS v3 base score of 3.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L).

CVE-2024-26277 has been assigned to this vulnerability. A CVSS v3 base score of 4.8 has been assigned; the CVSS vector string is (CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Energy
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Parasolid V35.1: Update to V35.1.254 or later version
  • Parasolid V36.0: Update to V36.0.207 or later version
  • Parasolid V36.1: Update to V36.1.147 or later version
  • Do not open untrusted XT files in Parasolid

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage

For more information see the associated Siemens security advisory SSA-222019 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Rockwell Automation 5015-AENFTXT

By: CISA
11 April 2024 at 08:00

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.7
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Rockwell Automation
  • Equipment: 5015-AENFTXT
  • Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to crash the device and impact availability for the affected system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Rockwell Automation ethernet/IP adapter products are affected:

  • 5015-AENFTXT: v35 and prior to v2.12.1

3.2 Vulnerability Overview

3.2.1 IMPROPER INPUT VALIDATION CWE-20

An input validation vulnerability exists among the affected products that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability.

CVE-2024-2424 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2024-2424. A base score of 8.7 has been calculated; the CVSS vector string is CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N.

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation recommends users update to v2.12.1.

Users using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply Security Best Practices, where possible.

For more information and to see Rockwell's detection rules, see Rockwell Automation's security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Siemens SIMATIC S7-1500

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 7.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SIMATIC S7-1500
  • Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Input Validation, Use After Free, Out-of-bounds Write

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attack to cause a heap-based buffer overflow, local privilege escalation, kernel information leak, and a denial-of-service condition.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Siemens products are affected:

  • Siemens SIMATIC S7-1500 TM MFP (GNU/Linux subsystem): All versions

3.2 Vulnerability Overview

3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source, this may lead to a denial-of-service condition. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a denial-of-service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. Also vulnerable are the OpenSSL pkey command line application when using the "-pubcheck" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-5678 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.2 IMPROPER INPUT VALIDATION CWE-20

An out-of-bounds read vulnerability was found in the NVMe-oF/TCP subsystem in the Linux kernel. This issue may allow a remote attacker to send a crafted TCP packet, triggering a heap-based buffer overflow that results in kmalloc data being printed and potentially leaked to the kernel ring buffer (dmesg).

CVE-2023-6121 has been assigned to this vulnerability. A CVSS v3 base score of 4.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N).

3.2.3 USE AFTER FREE CWE-416

A use-after-free vulnerability in the Linux kernel's netfilter: nf_tables component can be exploited to achieve local privilege escalation. The function nft_pipapo_walk did not skip inactive elements during set walk which could lead double deactivations of PIPAPO (Pile Packet Policies) elements, leading to use-after-free. We recommend upgrading past commit 317eb9685095678f2c9f5a8189de698c5354316a.

CVE-2023-6817 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.4 OUT-OF-BOUNDS WRITE CWE-787

A heap out-of-bounds write vulnerability in the Linux kernel's Performance Events system component can be exploited to achieve local privilege escalation. A perf_event's read_size can overflow, leading to a heap out-of-bounds increment or write in perf_read_group(). We recommend upgrading past commit 382c27f4ed28f803b1f1473ac2d8db0afc795a1b.

CVE-2023-6931 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.5 USE AFTER FREE CWE-416

A use-after-free vulnerability in the Linux kernel's ipv4: igmp component can be exploited to achieve local privilege escalation. A race condition can be exploited to cause a timer to be mistakenly registered on a RCU read locked object which is freed by another thread. We recommend upgrading past commit e2b706c691905fe78468c361aaabc719d0a496f1.

CVE-2023-6932 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.6 IMPROPER INPUT VALIDATION CWE-20

The Linux kernel before 6.5.4 has an es1 use-after-free in fs/ext4/extents_status.c, related to ext4_es_insert_extent.

CVE-2023-45898 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.7 USE AFTER FREE CWE-416

A use-after-free issue was found in igmp_start_timer in net/ipv4/igmp.c in the network sub-component in the Linux Kernel. This flaw allows a local user to observe a refcnt use-after-free issue when receiving an igmp query packet, leading to a kernel information leak.

CVE-2023-6121 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).

3.2.8 IMPROPER INPUT VALIDATION CWE-20

Processing a maliciously formatted PKCS12 file may lead OpenSSL to crash leading to a potential denial-of-service attack Impact summary: Applications loading files in the PKCS12 format from untrusted sources might terminate abruptly. A file in PKCS12 format can contain certificates and keys and may come from an untrusted source. The PKCS12 specification allows certain fields to be NULL, but OpenSSL does not correctly check for this case. This can lead to a NULL pointer dereference that results in OpenSSL crashing. If an application processes PKCS12 files from an untrusted source using the OpenSSL APIs then that application will be vulnerable to this issue. OpenSSL APIs that are vulnerable to this are: PKCS12_parse(), PKCS12_unpack_p7data(), PKCS12_unpack_p7encdata(), PKCS12_unpack_authsafes() and PKCS12_newpass(). We have also fixed a similar issue in SMIME_write_PKCS7(). However, since this function is related to writing data, we do not consider it security significant. The FIPS modules in 3.2, 3.1, and 3.0 are not affected by this issue.

CVE-2024-0727 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Only build and run applications from trusted sources.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-265688 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Siemens RUGGEDCOM APE1808

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 8.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: RUGGEDCOM APE1808
  • Vulnerabilities: Cross-site Scripting, Improper Privilege Management, Improper Check for Unusual or Exceptional Conditions, Truncation of Security-relevant Information, Insufficient Session Expiration

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow a malicious administrator to store a JavaScript payload using the web interface, revoke active XML API keys from the firewall and disrupt XML API usage, or cause a denial-of-service.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens RUGGEDCOM APE1808, an application hosting platform, are affected:

  • Siemens RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW configured with support for the CHACHA20-POLY1305 algorithm or any Encrypt-then-MAC algorithms (CVE-2023-48795)
  • Siemens RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW (CVE-2023-6789, CVE-2023-6793, CVE-2024-0008)
  • Siemens RUGGEDCOM APE1808: All versions with Palo Alto Networks Virtual NGFW that are configured with BGP routing features enabled (CVE-2023-38802)

3.2 Vulnerability Overview

3.2.1 IMPROPER NEUTRALIZATION OF INPUT DURING WEB PAGE GENERATION ('CROSS-SITE SCRIPTING') CWE-79

A cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS software enables a malicious authenticated read-write administrator to store a JavaScript payload using the web interface. Then, when viewed by a properly authenticated administrator, the JavaScript payload executes and disguises all associated actions as performed by that unsuspecting authenticated administrator.

CVE-2023-6789 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N).

A CVSS v4 score has also been calculated for CVE-2023-6789. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N).

3.2.2 IMPROPER PRIVILEGE MANAGEMENT CWE-269

An improper privilege management vulnerability in Palo Alto Networks PAN-OS software enables an authenticated read-only administrator to revoke active XML API keys from the firewall and disrupt XML API usage.

CVE-2023-6793 has been assigned to this vulnerability. A CVSS v3.1 base score of 2.7 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L).

A CVSS v4 score has also been calculated for CVE-2023-6793. A base score of 5.1 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N).

3.2.3 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

FRRouting FRR 7.5.1 through 9.0 and Pica8 PICOS 4.3.3.2 allow a remote attacker to cause a denial of service via a crafted BGP update with a corrupted attribute 23 (Tunnel Encapsulation).

CVE-2023-38802 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

3.2.4 TRUNCATION OF SECURITY-RELEVANT INFORMATION CWE-222

The SSH transport protocol with certain OpenSSH extensions, found in OpenSSH before 9.6 and other products, allows remote attackers to bypass integrity checks such that some packets are omitted from the extension negotiation message. A client and server may consequently end up with a connection for which some security features have been downgraded or disabled, aka a Terrapin attack. This occurs because the SSH Binary Packet Protocol (BPP) implemented by these extensions mishandles the handshake phase and mishandles use of sequence numbers.

CVE-2023-48795 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).

A CVSS v4 score has also been calculated for CVE-2023-48795. A base score of 8.2 has been calculated; the CVSS vector string is (CVSS4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N).

3.2.5 INSUFFICIENT SESSION EXPIRATION CWE-613

Web sessions in the management interface in Palo Alto Networks PAN-OS software do not expire in certain situations, making it susceptible to unauthorized access.

CVE-2024-0008 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • (CVE-2023-6789, CVE-2023-6793, CVE-2023-38802, CVE-2024-0008) RUGGEDCOM APE1808: Contact customer support to receive patch and update information.
  • (CVE-2023-48795) RUGGEDCOM APE1808: Currently no fix is available
  • (CVE-2023-48795) RUGGEDCOM APE1808: CVE-2023-48795: Customers can resolve this issue by configuring the in-use SSH profile to contain at least one cipher and at least one MAC algorithm, which removes support for CHACHA20-POLY1305 and all Encrypt-then-MAC algorithms available (ciphers with -etm in the name) in PAN-OS software. See Palo Alto Networks' upstream documentation https://security.paloaltonetworks.com/CVE-2023-48795 for additional guidance.

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-455250 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Siemens SINEC NMS

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 7.2
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: SINEC NMS
  • Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Limitation of a Pathname to a Restricted Directory

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to impact confidentiality, integrity, and availability.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens, are affected:

  • SINEC NMS: All versions prior to V2.0 SP2

3.2 Vulnerability Overview

3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754

Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial-of-Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() does not make any of these checks and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn't check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial-of-Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the "-pubcheck" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2023-5678 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).

3.2.2 IMPROPER LIMITATION OF A PATHNAME TO A RESTRICTED DIRECTORY ('PATH TRAVERSAL') CWE-22

Generating excessively long X9.42 DH keys or checking excessively long X9.42 DH keys or parameters may be very slow. Impact summary: Applications that use the functions DH_generate_key() to generate an X9.42 DH key may experience long delays. Likewise, applications that use DH_check_pub_key(), DH_check_pub_key_ex() or EVP_PKEY_public_check() to check an X9.42 DH key or X9.42 DH parameters may experience long delays. Where the key or parameters that are being checked have been obtained from an untrusted source this may lead to a Denial-of-Service. While DH_check() performs all the necessary checks (as of CVE-2023-3817), DH_check_pub_key() doesn't make any of these checks, and is therefore vulnerable for excessively large P and Q parameters. Likewise, while DH_generate_key() performs a check for an excessively large P, it doesn't check for an excessively large Q. An application that calls DH_generate_key() or DH_check_pub_key() and supplies a key or parameters obtained from an untrusted source could be vulnerable to a Denial-of-Service attack. DH_generate_key() and DH_check_pub_key() are also called by a number of other OpenSSL functions. An application calling any of those other functions may similarly be affected. The other functions affected by this are DH_check_pub_key_ex(), EVP_PKEY_public_check(), and EVP_PKEY_generate(). Also vulnerable are the OpenSSL pkey command line application when using the "-pubcheck" option, as well as the OpenSSL genpkey command line application. The OpenSSL SSL/TLS implementation is not affected by this issue. The OpenSSL 3.0 and 3.1 FIPS providers are not affected by this issue.

CVE-2024-31978 has been assigned to this vulnerability. A CVSS v3 base score of 7.6 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H).

CVE-2024-31978 has been assigned to this vulnerability. A CVSS v4 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-128433 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs). Recognize VPNs may have vulnerabilities, should be updated to the most recent version available, and are only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

CISA Releases Nine Industrial Control Systems Advisories

By: CISA
11 April 2024 at 08:00

CISA released nine Industrial Control Systems (ICS) advisories on April 11, 2024. These advisories provide timely information about current security issues, vulnerabilities, and exploits surrounding ICS.

CISA encourages users and administrators to review the newly released ICS advisories for technical details and mitigations.

Siemens SIMATIC WinCC

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v4 6.9
  • ATTENTION: Low attack complexity
  • Vendor: Siemens
  • Equipment: SIMATIC PCS 7, SIMATIC WinCC
  • Vulnerability: Classic Buffer Overflow

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow a local attacker to cause a denial-of-service condition in the runtime of the SCADA system.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Siemens SIMATIC PCS 7 and SIMATIC WinCC, a SCADA system, are affected:

  • Siemens SIMATIC PCS 7 V9.1: All versions before V9.1 SP2 UC04
  • Siemens SIMATIC WinCC Runtime Professional V17: All versions
  • Siemens SIMATIC WinCC Runtime Professional V18: All versions
  • Siemens SIMATIC WinCC Runtime Professional V19: All versions before V19 Update 1
  • Siemens SIMATIC WinCC V7.5: All versions before V7.5 SP2 Update 16
  • Siemens SIMATIC WinCC V8.0: All versions

3.2 Vulnerability Overview

3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120

The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial-of-service condition.

CVE-2023-50821 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.2 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).

A CVSS v4 score has also been calculated for CVE-2023-50821. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported this vulnerability to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • All affected products: Activate SIMATIC Logon in the User Administrator of the SIMATIC PCS 7 Operator Stations
  • SIMATIC WinCC Runtime Professional V17: Currently no fix is available
  • SIMATIC WinCC Runtime Professional V18: Currently no fix is available
  • SIMATIC WinCC V8.0: Currently no fix is available
  • SIMATIC WinCC Runtime Professional V19: Update to V19 Update 1 or later version
  • SIMATIC WinCC V7.5: Update to V7.5 SP2 Update 16 or later version
  • SIMATIC PCS 7 V9.1: Update to V9.1 SP2 UC04 or later version

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-730482 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Siemens Scalance W1750D

By: CISA
11 April 2024 at 08:00

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 

View CSAF

1. EXECUTIVE SUMMARY

  • CVSS v3 9.8
  • ATTENTION: Exploitable remotely/low attack complexity
  • Vendor: Siemens
  • Equipment: Scalance W1750D
  • Vulnerabilities: Classic Buffer Overflow

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to exploit buffer overflow and information disclosure vulnerabilities which could lead to information disclosure or unauthenticated remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following products of Siemens Scalance W1750D, a direct access point, are affected:

  • Siemens SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0): All versions prior to V8.10.0.9
  • Siemens SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0): All versions prior to V8.10.0.9
  • Siemens SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0): All versions prior to V8.10.0.9

3.2 Vulnerability Overview

3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's access point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system.

CVE-2023-35980 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.2 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's access point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system.

CVE-2023-35981 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.3 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120

There are buffer overflow vulnerabilities in multiple underlying services that could lead to unauthenticated remote code execution by sending specially crafted packets destined to the PAPI (Aruba's access point management protocol) UDP port (8211). Successful exploitation of these vulnerabilities results in the ability to execute arbitrary code as a privileged user on the underlying operating system.

CVE-2023-35982 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

  • CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
  • COUNTRIES/AREAS DEPLOYED: Worldwide
  • COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Siemens reported these vulnerabilities to CISA.

4. MITIGATIONS

Siemens has identified the following specific workarounds and mitigations users can apply to reduce risk:

  • Update to V8.10.0.9 or later version. The update is available upon request from customer support
  • The CLI and web-based management interfaces should be restricted to a dedicated layer 2 segment/VLAN and/or controlled by firewall policies at layer 3 and above
  • Enabling cluster-security via the cluster-security command will prevent the vulnerabilities from being exploited

As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for industrial security and following recommendations in the product manuals.

Additional information on industrial security by Siemens can be found on the Siemens industrial security webpage.

For more information see the associated Siemens security advisory SSA-885980 in HTML and CSAF.

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

  • Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
  • Locate control system networks and remote devices behind firewalls and isolating them from business networks.
  • When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

  • April 11, 2024: Initial Publication

Compromise of Sisense Customer Data

By: CISA
11 April 2024 at 08:00

CISA is collaborating with private industry partners to respond to a recent compromise discovered by independent security researchers impacting Sisense, a company that provides data analytics services.

CISA urges Sisense customers to:

  • Reset credentials and secrets potentially exposed to, or used to access, Sisense services. 
  • Investigate—and report to CISA—any suspicious activity involving credentials potentially exposed to, or used to access, Sisense services.

CISA is taking an active role in collaborating with private industry partners to respond to this incident, especially as it relates to impacted critical infrastructure sector organizations. We will provide updates as more information becomes available.
 

Fortinet Releases Security Updates for Multiple Products

By: CISA
9 April 2024 at 08:00

Fortinet released security updates to address vulnerabilities in multiple products, including OS and FortiProxy. A cyber threat actor could exploit some of these vulnerabilities to take control of an affected system. 

CISA encourages users and administrators to review the following advisories and apply necessary updates: 

❌
❌